Copper Underground Drop Wire 1 Pair Telephone Cable

Customization: Available
Application: Local Communication Cable, Long Distance Symmetric Cable, Submarine Cable
Conductor Material: Copper

Products Details

Basic Info.

Model NO.
Telephone Cable HYV CAT3
Type
Cat 3
Material Shape
Round Wire
Conductor Type
Solid
Wire Core Material
Bare Copper Wire
Certification
CE, ISO, RoHS
Model
MHYV-xx
Brand
Hanli
Transport Package
305/1000
Specification
0.5CU
Trademark
HANLI
Origin
Zhejiang
HS Code
8544491100
Production Capacity
2000000m/Month

Product Description

Telephone cable

Solid PE Insulated & PE Sheathed Air Core Cables to CW 1171
 
Application
The cables are designed for use as subscriber distribution cables and as connection between central offices in local access networks. The cables are unfilled and capable of being pressurized when installed. The cables are suitable for installation in ducts.
Standards
    
• CW 1171 (For unscreened cable)
• CW 1179 (For screened cable)
• CW 1252 (For self-supporting cable)
Construction
Conductors: Solid annealed bare copper, 0.32/0.4/0.5/0.63/0.9mm as per BS 6360/IEC 60228 Class 1 
Insulation: Solid polyethylene as per BS EN 50290-2-23/BS 6234/IEC 60708
Twisted Pairs: Insulated conductors are twisted into pairs with varying lay length to minimize crosstalk.
Cabling Element: Twisted Pairs
Cable Core Assembly: Cables with 100 pairs or less are composed of 25-pair units or 12/13-pair units; cables with over 100 pairs are composed of 25, 50 or 100-pair units. Standard construction is per CW 1171 given in Cable Make Up Chart
Core Wrapping: One or more non-hygroscopic polyester tapes are helically or longitudinally laid with an overlap. These tapes furnish thermal, mechanical as well as high dielectric protection between shielding and individual conductors
Moisture Barrier (optional):A layer of aluminium tape (0.15mm) coated with PE-copolymer on one or both sides is applied longitudinally with overlap over the cable core to provide shielding coverage and ensure a barrier against water vapor
Sheath: Black low density polyethylene as per BS 6234/IEC 60708, being able to withstand exposure to sunlight, temperature variations, ground chemicals and other environmental contaminants
Ripcord:Ripcord may be provided for slitting the sheath longitudinally to facilitate its removal 
Spare Pairs (optional):Spare pairs may be incorporated for 200 and larger pair cables
Continuity Wire (optional): Tinned copper drain wire may be longitudinally laid to ensure electrical continuity of the screen
Electrical & Mechanical Properties
Nominal Conductor Diameter mm 0.32 0.4 0.5 0.63 0.9
Conductor Gauge Size AWG 28 26 24 22 19
Conductor Size mm2 0.08 0.126 0.196 0.312 0.636
Maximum Average Conductor Resistance @20°C /km 223 143 91 58 28
Minimum Insulation Resistance @500V DC M.km 6500 6500 6500 6500 6500
Maximum Average Mutual Capacitance @800Hz nF/km 53/68* 53 53 56 59
Maximum Individual Mutual Capacitance @800Hz (for 99% cases) nF/km 60/75* 60 60 60 64
Maximum Individual Capacitance Unbalance @800Hz pair-to-pair pF/500m 275 275 275 275 275
Maximum Conductor Loop Resistance @20°C /km 470 300 192 114 60
Impedance @1KHz   1000 994 796 660 445
Impedance @100KHz   156 147 134 125 122
Impedance @512KHz   122 120 118 117 116
Impedance @1MHz   120 117 115 114 113
Maximum Average Attenuation @0.8KHz dB/km 1.76 1.64 1.30 1.04 0.74
Maximum Average Attenuation @1KHz dB/km 1.8 1.68 1.35 1.08 0.76
Maximum Average Attenuation @3KHz dB/km 3.4 3.18 2.52 2.01 1.42
Maximum Average Attenuation @150KHz dB/km 16.8 11.4 8.3 6.2 4.4
Maximum Average Attenuation @772KHz dB/km 29.5 24.3 19.4 15.4 10.8
Maximum Average Attenuation @1000KHz dB/km 33.5 27.1 21.4 17.5 12.8
Dielectric Strength Conductor to Conductor (3secs) V DC 500 500 500 500 500
Nominal Insulation Thickness mm 0.145/0.08** 0.175 0.20 0.26 0.3
Nominal Insulated Conductor Diameter mm 0.61/0.48** 0.75 0.90 1.15 1.5
* Mutual capacitance values may be increased by 3% for cables with a nominal number of pairs less than 400.
The values apply to 4000 and 4800 pairs 0.32mm cable only.
Mechanical and Thermal Properties
Temperature range during operation (fixed state): -30°C - +70°C
Temperature range during installation (mobile state): -20°C - +50°C 
Minimum bending radius: 10 x Overall Diameter (unarmoured cables);15 x Overall Diameter (armoured cables)
Colour Code Standard colour code is per CW 1171 given in Colour Code Chart 
Dimensions And Weight Solid PE Insulated & PE Sheathed Air Core Cables to CW 1171
Copper Underground Drop Wire 1 Pair Telephone CableCopper Underground Drop Wire 1 Pair Telephone Cable
Copper Underground Drop Wire 1 Pair Telephone CableCopper Underground Drop Wire 1 Pair Telephone CableCopper Underground Drop Wire 1 Pair Telephone Cable

Welcome to visit our factory and  get our samples.
  Your inquiry will be answered within 24 hours .Wishing to be your long- term partner ,please feel free to contact me ,we will do our best for you. 
 
Choose us, won't make you disappointed:
1.6years manufactory experience 
2.OEM/ODM available
3.Steady product quality
4.Strict quality control
5.Strictly conform to CE,ROHS,Iso9001
6.Quick delivery time(20ft,25days)
  Contact:
   Name: Carey zhu 

Website: http://kuayuecable.en.made-in-china.com   

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours